ID |
Date |
Author |
Author Email |
Category |
Subject |
Status |
Last Revision |
14
|
Fri Jul 8 17:34:02 2005 |
Emiliano Gabrielli | AlberT@SuperAlberT.it | Script | JavaScript list auto-refresh | Stable | Tue Jul 12 12:36:16 2005 by Emiliano Gabrielli |
Here is a simple piece of JS code to accomplish a smart page reload.
We don't reload if in some kind of editing mode.
You can put the code everywhere you like in the elog html page, my suggestion is to put it in Bottom Text (or Top Text):
;auto-refresh
Bottom text = [I]<script language="JavaScript">if (null==window.location.href.match('/[0-9]+$|.*(cmd|select)=.*') ) { window.setTimeout("location.reload();", 2*60*1000); now=new Date(); document.write('<br/>Last reload at '+now.getFullYear()+'/'+(now.getMonth()+1)+'/'+now.getDate()+', '+( ((h=now.getHours())<10) ? '0'+h :h)+':'+( ((m=now.getMinutes())<10) ? '0'+m :m)+':'+( ((s=now.getSeconds())<10) ? '0'+s :s)) }</script>[/I]
the timer is a product of # of minutes, #of seconds and milliseconds... 2 minutes in the above example 
Revision Tue Jul 12 12:36:16 2005 wrote: |
modified regular expression in order to not activate the auto-refresh in the signle entry view
|
|
36
|
Tue Aug 23 12:07:51 2011 |
Stefan Ritt | stefan.ritt@psi.ch | Script | Re: JavaScript list auto-refresh | Stable | Tue Jul 12 12:36:16 2005 by Emiliano Gabrielli |
Emiliano Gabrielli wrote: | Here is a simple piece of JS code to accomplish a smart page reload.
We don't reload if in some kind of editing mode.
You can put the code everywhere you like in the elog html page, my suggestion is to put it in Bottom Text (or Top Text):
;auto-refresh
Bottom text = [I]<script language="JavaScript">if (null==window.location.href.match('/[0-9]+$|.*(cmd|select)=.*') ) { window.setTimeout("location.reload();", 2*60*1000); now=new Date(); document.write('<br/>Last reload at '+now.getFullYear()+'/'+(now.getMonth()+1)+'/'+now.getDate()+', '+( ((h=now.getHours())<10) ? '0'+h :h)+':'+( ((m=now.getMinutes())<10) ? '0'+m :m)+':'+( ((s=now.getSeconds())<10) ? '0'+s :s)) }</script>[/I]
the timer is a product of # of minutes, #of seconds and milliseconds... 2 minutes in the above example 
Revision Tue Jul 12 12:36:16 2005 wrote: |
modified regular expression in order to not activate the auto-refresh in the signle entry view
|
|
Starting with SVN revision 2422, there is a new config option
refresh = <seconds>
which lets you do the same thing. |
153
|
Tue Dec 7 01:38:23 2021 |
Anthony J Krishock | ajkrishock@gmail.com | Theme/Skin | Astronomical logbook using Elog | Stable | Tue Dec 7 01:44:25 2021 by Anthony J Krishock |
Hello all,
I became aware of the usefulness of Elog while working at Brookhaven National Lab. Since that time, I have developed a version of Elog that can be used as a log book for observations in Astronomy (my longtime hobby). Attached is my default.css theme and replacement icon files that match the theme. The color scheme is chosen to minimize bright lights and preserve night vision
To install, just place the default.css file in the default theme directory and copy over the icon files into the default theme directory and replace the default ones.
Comments and suggestions welcome!
Thank you |
154
|
Thu Mar 3 12:01:55 2022 |
rami khrais | rami.khrais@sesame.org.jo | Other | Fixing repeating first inline_image in email | Stable | Thu Mar 10 11:30:20 2022 by rami khrais |
Fixing repeating first image in email (email notification) when the user submit a new log with in_line images. |
22
|
Wed Jul 11 11:13:16 2007 |
Peter Rienstra | peter.rienstra@gmail.com | Other | Compiling elogd.c on HP-UX 64 bit | Beta | Thu Jul 12 09:38:47 2007 by Peter Rienstra |
We succeeded in compiling and running elogd (elog-2.6.5) on HP-UX 64 bit Itanium platform (HP-UX B.11.23 U ia64).
The main problem was we got a core dump after starting elogd. The cause was that the memory has be allocated with a 4 byte boundary. This could be the case on other 64 bit platforms as well. A colleague of mine (Sander Notting) found the solution.
Unzip and untar the zip file (elog-latest.tar.gz)
Go to the src directory (elog-2.6.5/src)
Edit elogd.c
Replace all:
show_selection_page(NULL); => show_selection_page();
seteuid => setuid
setegid => setgid
On line 564:
void *buffer => char *buffer
Line 645, add the text in bold:
void *xmalloc(size_t bytes)
{
char *temp;
/* Align buffer on 4 byte boundery for HP UX and other 64 bit systems to prevent Bus error(core dump)*/
if (bytes & 3)
bytes += 4 - (bytes & 3);
temp = (char *) malloc(bytes + 12);
After that compile:
cc -w -c -o regex.o regex.c
cc -w -c -o mxml.o ../../mxml/mxml.c
cc -w -c -o strlcpy.o ../../mxml/strlcpy.c
cc -I../../mxml -o elogd elogd.c regex.o mxml.o strlcpy.o
We didn't try to run elogd under root yet. |
23
|
Fri Jul 13 12:36:45 2007 |
Stefan Ritt | stefan.ritt@psi.ch | Other | Re: Compiling elogd.c on HP-UX 64 bit | Beta | Thu Jul 12 09:38:47 2007 by Peter Rienstra |
I applied most of your patches to the elog source code, SVN revision 1885. The only missing piece has to do with seteuid/setuid. I definitively need seteuid for linux, because elogd might be started under root, then it falls back to an optional elog user. But when it stops, it has to restore the original root user in order to delete the PID file (/var/run/elogd.pid) which was created under root. If seteuid does not exist under HP-UX, you should add something like
#ifdef HP-UX
setuid(...)
#else
seteuid(...)
#endif
Probably the HP-UX has to be something else, but I cannot test this since I don't have such an OS here. Once you get this working I can put it into the standard distribution. |
24
|
Mon Jul 16 15:27:08 2007 |
Peter Rienstra | peter.rienstra@gmail.com | Other | Re: Compiling elogd.c on HP-UX 64 bit | Beta | Thu Jul 12 09:38:47 2007 by Peter Rienstra |
Stefan,
First I want to say I really like your program. We work in a small group of 5 database administrators, and this is exactly what we need to inform each other. Elog is simple but very functional, so thanks!
My problem is that I don't have root access to the HP-UX machines. We don't run elogd as root, so I wasn't really interested in the seteuid functionality, I just wanted to compile and run the program.
HP-UX doesn't have the "seteuid" and "setegid" functions. But there are "setuid+setgid", "setreuid+setregid" and "setresuid+setresgid" functions available. I'm not sure which one is the best to use. I uploaded the manpages as attachment. I hope this will help you.
If you want I can do a compile and run test on HP-UX with your altered source code. But I can't do a test with "root".
Stefan Ritt wrote: | I applied most of your patches to the elog source code, SVN revision 1885. The only missing piece has to do with seteuid/setuid. I definitively need seteuid for linux, because elogd might be started under root, then it falls back to an optional elog user. But when it stops, it has to restore the original root user in order to delete the PID file (/var/run/elogd.pid) which was created under root. If seteuid does not exist under HP-UX, you should add something like
#ifdef HP-UX
setuid(...)
#else
seteuid(...)
#endif
Probably the HP-UX has to be something else, but I cannot test this since I don't have such an OS here. Once you get this working I can put it into the standard distribution. |
|
25
|
Mon Jul 16 15:57:47 2007 |
Stefan Ritt | stefan.ritt@psi.ch | Other | Re: Compiling elogd.c on HP-UX 64 bit | Beta | Thu Jul 12 09:38:47 2007 by Peter Rienstra |
Peter Rienstra wrote: | HP-UX doesn't have the "seteuid" and "setegid" functions. But there are "setuid+setgid", "setreuid+setregid" and "setresuid+setresgid" functions available. |
I had a look and found that setreuid/setregid is also available under Linux, so I use those functions instead, which should also work on HP-UX. Can you check revision 1888 (http://savannah.psi.ch/viewcvs/trunk/src/elogd.c?root=elog&rev=1888), compile it and see if you can run it at least under your non-root account. |
26
|
Mon Jul 16 16:43:07 2007 |
Peter Rienstra | peter.rienstra@gmail.com | Other | Re: Compiling elogd.c on HP-UX 64 bit | Beta | Thu Jul 12 09:38:47 2007 by Peter Rienstra |
I downloaded revision 1888. There were no problems compiling it. It's running on the HP-UX system now and everything seems to work fine.  |
39
|
Fri Sep 17 06:19:39 2010 |
Stefan Ritt | stefan.ritt@psi.ch | Script | Custom input forms implementation | Stable | Thu Jul 2 20:55:55 2015 by Stefan Ritt |
Dear ELOG users,
starting with SVN revision 2328, custom input forms are implemented. This allows application specific formats for check lists etc. In our specific case we had to implement a shift check list, which was quite long. Furthermore the check list should be optimized for an iPad, which we take in the field and record various checks and readings (in our case some gas pressure gauges at the PSI particle accelerator). Since the standard ELOG interface was too inflexible, a completely hand-written form was needed. The form can be activated by the new configuration options Custom New Form, Custom Edit Form and Custom Display Form, one for a new entry, an entry to edit and and entry to display. In our case we used the same form for all three cases. This is how the shift check list looks under the Safari Browser on a PC:

And here is how it looks on the iPad:

Each section can be collapsed and expanded (blue arrows at the left), and various internal checks are made before the check list can be submitted.
Implementing such forms is however more something for the advanced user, since you have to hand-write HTML with CSS and JavaScript code. It can then however be a powerful method for check lists. Please find in the attachments the elogd.cfg configuration for that logbook and the shiftcheck.html source code file. It is a bit complicated since the page is a static page, elogd just serves it from the file. This requires all the dynamic functions to be implemented inside the HTML file with JavaScript. To display an entry for example, the JavaScript loads the raw data with the "?cmd=Download" command and the populates the form fields. The collapsing and expanding is done by using CSS properties. The integrated style sheet was optimized for the rendering on an iPad. Rather large fonts were chosen so that the items can be checked easily with your finger tips. Various parameters are sent between the browser and the elogd program via hidden fields and cookies. So only something for experts! But if you go through the effort and hand-write the form, it can be very handy. Note that you have to upgrade to SVN revision 2328 for the three new options.
|