Public Collaboration Sub-groups Archive
News Publication List
  List of MEG publications, Page 10 of 18  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Year Type Titledown Conference Journal
2001PSI Annual reportMUEGAMMA Prototype Timing Counter Tests PSI Annual Report 01
Attachment 1: muegamma.ps
muegamma.ps muegamma.ps
Attachment 2: muegamma.tex
\title{MuEgamma Prototype Timing Counter Tests}
\author{
}

% You can optionally add the proposal numer and institutes, e.g.
\collaboration{R--99--05  }{MuEGamma Collaboration : BINP Novosibirsk -- ICEPP Tokyo -- INFN Pisa -- IPNS KEK\\ 
-- Nagoya -- PSI -- Waseda}

\begin{contribution}

The aim of the $\bf{MuEGamma}$ experiment is to search for the lepton-flavour violating decay $\mu \rightarrow {\mathrm{e}} \gamma$ to a sensitivity of $\sim 10^{-14}$, more than two orders of magnitude lower than the current search limit set by the MEGA-experiment at LAMPF \cite{mega99}. In order to achieve this goal, a detector capable of handling the intense surface muon rate, produced by the $\pi$E5 beam at PSI, and able to resolve the positron and photon from the decay with the best possible momentum/energy-, positional- and timing-resolutions, is required.

The main detector components, are shown in Fig.\ref{fig:muEgamma-fig1}. Surface muons of 28~MeV/c enter the thin-coil, superconducting solenoid and are stopped in a small, thin target. The subsequent decay of the muon leads to a Michel positron, which exhibits a spiral path with increasing pitch, the bending radius of which depends entirely on its total momentum and is 'independent' of its emission angle. These novel features are achieved by the gradient field of the solenoid magnet, with a maximum field strength of 1.27~T at the centre of the detector and decreasing axially. The positron momentum and angle are determined by tracking the particle with a set of azimuthally spaced, staggered-cell drift chambers, while the energy, timing and angle of the photon are obtained from a liquid Xenon calorimeter, viewed from all sides by some 800 photomultiplier tubes. The timing of the positron and hence the trigger condition for coincident back-to-back decay products, is given by a set of fast, double-layered, orthogonally placed, scintillator timing-counter arrays, positioned at opposite ends of the detector.

\begin{figure}[htb]
   \centering
   \includegraphics[width=0.85\linewidth=3.0]{muEgamma-fig1.eps}
\caption{\small\slshape Plan View of the MuEgamma Detector showing the main components, as well as an example of the decay trajectories of the positron and photon.}
\label{fig:muEgamma-fig1}
\end{figure}                                      

%\vspace{-2mm}

Several timing-counter prototypes were built and tested at the cosmic ray test facility CORTES at INFN Pisa.
The results reported below are for a (100 x 5 x 1) $cm^{3}$ Bicron 404 scintillator bar, wrapped with 50 $\mu$m of aluminized Mylar foil and coupled to Philips XP2020 UR photomultiplier tubes (PMTs) at either end. Tests were also done with Hamamatsu R5946 fine mesh tubes and variously shaped light guides.

The CORTES facility consists of a set of cosmic trigger counters, placed above and below the central tracking region, with two sets of four planes of Microstrip Gas Chambers (MSGCs) \cite{Bellazzini2001}. The dimensions of each chamber are 10 cm x 10 cm. Each set of the four planes of MSGCs provides two sets of orthogonal coordinates via two stereo planes inclined at 5.7$\,^\circ$. Two additional fast timing counters, placed behind each other and just below the upper trigger counter give a good timing reference signal for the scintillator bar to be tested, which is placed between the two sets of MSGCs. The track impact point along the  counter to be tested was reconstructed with a resolution better than 1 mm.

The cosmic muon timing, relative to the reference counters, is independently measured by each of the PMTs at either end of the counter, after corrections are made for "time-walk" effects. The resultant resolutions are shown in Fig.\ref{fig:muEgamma-fig2}. The weighted average of the two measurements is of the order of $\sim$ 60 ps, independent of the position along the counter. It was also checked that the timing resolution depends on 

\begin{figure}[h]
   \centering
   \includegraphics[width=0.9\linewidth=3]{muEgamma-fig2.ps}
\caption{\small\slshape Timing resolutions measured along the length of the counter.}
\label{fig:muEgamma-fig2}
\end{figure} 

%\vspace{-1mm}

\noindent                                     
the square-root of the total number of photoelectrons. A full Monte Carlo simulation, taking into account the measured values, shows that the required 40 ps timing resolution stated in the proposal, will be obtained with a suitable counter geometry, the engineering studies of which are in progress. 

\vspace{2mm}
\begin{thebibliography}{9}

\bibitem{mega99}
M.~L.~Brooks {\it et~al.},\\
Phys.~Rev.~Lett {\bf 83}, 1521 (1999).

\bibitem{Bellazzini2001}
R.~Bellazzini {\it et~al.},\\
Nucl.~Instr.~and Meth. {\bf A~457}, 22 (2001).
\end{thebibliography}

\end{contribution}

2003ConferenceMIDAS short course13th IEEE-NPSS Real Time Conference 
2008Conference with proceedingsMEG: lepton flavour violation in mu^+ to e^+ gammaIFAE 2008Il Nuovo Cimento
2006Conference with proceedingsMEG: The experiment to search for µ → eγ9th International Workshop on Tau Lepton Physics (Tau06)Nucl. Phys. B Proc. Suppl.
2013Conference with proceedingsMEG: Status and Upgrades1st International Conference on Charged Lepton Flavor Violation (CLFV2013)Nucl. Phys. B Proc. Suppl.
2021Conference with proceedingsMEG: Muon to Electron and GammaReview of Particle Physics at PSI (PSI2020)SciPost Phys. Proc.
2012Conference with proceedingsMEG, µ+ → e+γ search at Paul Scherrer InstituteInternational Workshop on Grand Unified Theories (GUT2012)AIP Conf. Proc.
2010Conference with proceedingsMEG simulation and analysis softwareIEEE Nuclear Science Symposium & Medical Imaging Conference (NSS/MIC)IEEE NSS/MIC
2010Conference with proceedingsMEG liquid xenon detector1st International Workshop towards the Giant Liquid Argon Charge Imaging Experiment (GLA 2010)J. Phys. Conf. Ser.
Attachment 1: mihara-GLA2010.pdf
mihara-GLA2010.pdf mihara-GLA2010.pdf mihara-GLA2010.pdf mihara-GLA2010.pdf mihara-GLA2010.pdf mihara-GLA2010.pdf mihara-GLA2010.pdf mihara-GLA2010.pdf
2004ArticleMEG goes in search of the forbidden CERN Courier
2018Conference with proceedingsMEG final results and progress towards MEG II15th International Workshop on Tau Lepton Physics (TAU2018)SciPost Phys. Proc.
2010Conference with proceedingsMEG experiment: New result and prospects12th International Workshop on Neutrino Factories, Superbeams and Beta beams (NuFact10)AIP Conf. Proc.
2003ConferenceMEG experiment: A new experiment to search for mu->e gamma at PSIXXI International Symposium on Lepton and Photon Interactions at High Energies (LP03) 
Attachment 1: lp2003ootani.pdf
lp2003ootani.pdf
2009Conference with proceedingsMEG experiment at the Paul Scherrer Insitute4th International Symposium on Symmetries in Subatomic Physics (SSP 2009)Nucl. Phys. A
2007ConferenceMEG Status and ProspectsThe 6th KEK Topical Conference (KEKTC6) 
Attachment 1: kektc6.ppt
2023Conference with proceedingsMEG II physics and detector performanceNew Frontiers in Lepton Flavor 2023 (NeFLeF23)JINST
2017Conference with proceedingsMEG II liquid xenon scintillation calorimeter to detect 52.8 MeV γ with large area VUV-sensitive MPPCs8th International Conference on New Developments In Photodetection (NDIP17)Nucl. Instrum. Meth. A
2021Conference with proceedingsMEG II experiment status and prospect22nd International Workshop on Neutrinos from Accelerators (NuFact2021)PoS
Attachment 1: NuFact2021_120.pdf
NuFact2021_120.pdf NuFact2021_120.pdf NuFact2021_120.pdf NuFact2021_120.pdf NuFact2021_120.pdf NuFact2021_120.pdf
2015Conference with proceedingsMEG II drift chamber characterization with the silicon based cosmic ray tracker at INFN Pisa13th Pisa Meeting on Advanced Detectors (PM2015)Nucl. Instrum. Meth. A
2019Conference with proceedingsMEG II and Mu3e status and plan12th International Workshop on e+e- collisions from Phi to Psi (PhiPsi19)EPJ Web Conf.
Attachment 1: epjconf_phipsi18_01004.pdf
epjconf_phipsi18_01004.pdf epjconf_phipsi18_01004.pdf epjconf_phipsi18_01004.pdf epjconf_phipsi18_01004.pdf epjconf_phipsi18_01004.pdf epjconf_phipsi18_01004.pdf epjconf_phipsi18_01004.pdf epjconf_phipsi18_01004.pdf
ELOG V3.1.5-3fb85fa6