Public Collaboration Sub-groups Archive
News Publication List
  List of MEG publications, Page 15 of 16  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Year Type Titledown Conference Journal
2015Conference with proceedingsA new cylindrical drift chamber for the MEG II experiment13th Pisa Meeting on Advanced Detectors (PM2015)Nucl. Instrum. Meth. A
2015Conference with proceedingsA new assembly technique of full stereo Drift Chamber for high energy physics experiments2015 6th International Workshop on Advances in Sensors and Interfaces (IWASI)IWASI
2022Conference with proceedingsA liquid hydrogen target to fully characterize the new MEG II liquid xenon calorimeter15th Pisa Meeting on Advanced Detectors (PM2021)Nucl. Instrum. Meth. A
Attachment 1: 1-s2.0-S0168900223000104-main.pdf
1-s2.0-S0168900223000104-main.pdf 1-s2.0-S0168900223000104-main.pdf 1-s2.0-S0168900223000104-main.pdf
2024Conference with proceedingsA liquid hydrogen target for the calibration of the MEG-II LXe calorimeter16th Pisa Meeting on Advanced Detectors (PM2024)Nucl. Instrum. Meth. A
Attachment 1: 1-s2.0-S0168900224007629-main.pdf
1-s2.0-S0168900224007629-main.pdf 1-s2.0-S0168900224007629-main.pdf
2015Conference with proceedingsA liquid hydrogen target for the calibration of the MEG and MEG II liquid xenon calorimeter13th Pisa Meeting on Advanced Detectors (PM2015)Nucl. Instrum. Meth. A
2010ArticleA limit for the mu -> e gamma decay from the MEG experiment Nuclear Physics B
A search for the decay mu -> e gamma, performed at PSI and
based on data from the initial three months of operation of the MEG
experiment, yields an upper limit
BR(mu -> e gamma) < 2.8 x 10**-11 (90% C.L.).
Positrons and photons from ~ 10**14 stopped mu-decays
were measured by a superconducting positron spectrometer and a
900 litre liquid xenon photon detector.

 

2015Conference with proceedingsA high resolution Timing Counter for the MEG II experiment13th Pisa meetingNucl. Instrum. Methods A
2015Conference with proceedingsA high performance front end for MEG II tracker2015 6th International Workshop on Advances in Sensors and Interfaces (IWASI)IWASI
2015Conference with proceedingsA high performance Front End Electronics for drift chamber readout in MEG experiment upgrade13th Pisa Meeting on Advanced Detectors (PM2015)Nucl. Instrum. Meth. A
2015Conference with proceedingsA dedicated calibration tool for the MEG and MEG II positron spectrometer13th Pisa Meeting on Advanced Detectors (PM2015)Nucl. Instrum. Meth. A
2006ArticleA cryogenic facility for testing the PMTs of the MEG liquid xenon calorimeter Nucl. Instrum. Meth. A
Abstract

We built and operated a cryogenic facility for testing in liquid xenon the photomultipliers (PMTs) to be used in the electromagnetic calorimeter of the MEG experiment. In this paper we describe the working principle of the facility and we report on the characteristics measured for some PMTs.

Keywords: Photomultipliers; Calibration; Liquid xenon; Calorimeters; Scintillation light, detectors, cryogenic detectors

PACS classification codes: 85.60.Ha; 06.20.Fn; 07.20.Mc; 07.20.Fw; 29.40.Mc
2014Conference with proceedingsA Pixelated Positron Timing Counter with Fast Plastic Scintillator Readout by SiPMs for the MEG IITIPP 2014PoS
Attachment 1: TIPP2014_313.pdf
TIPP2014_313.pdf TIPP2014_313.pdf TIPP2014_313.pdf TIPP2014_313.pdf
2000ConferenceA New Experiment to Search for mu -> e gamma at PSIKEK Theory Workshop on Present Status and Prospects of Particle Physics 
2018Conference with proceedingsA Laser-based Time Calibration System for the MEG II Timing Counter2018 IEEE NSS & MIC2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC)
2015Conference with proceedingsA High Resolution Timing Counter for the MEG II ExperimentIEEE NSS-MIC 2015 
2022Conference with proceedingsA 10^-3 drift velocity monitoring chamber for the MEG II experiment15th Pisa Meeting on Advanced Detectors (PM2021)Nucl. Instrum. Meth. A
Attachment 1: 1-s2.0-S0168900222010294-main.pdf
1-s2.0-S0168900222010294-main.pdf 1-s2.0-S0168900222010294-main.pdf
2008Conference with proceedings900-L liquid xenon cryogenic system operation for the MEG experiment22nd International Cryogenic Engineering Conference and 2008 International Cryogenic Materials Conference (ICEC 22 - ICMC 2008) 
Attachment 1: 001_ICEC_22_-_27.pdf
001_ICEC_22_-_27.pdf 001_ICEC_22_-_27.pdf 001_ICEC_22_-_27.pdf 001_ICEC_22_-_27.pdf 001_ICEC_22_-_27.pdf
2016Conference with proceedings30-ps time resolution with segmented scintillation counter for MEG IIVCI 2016Nucl. Instrum. Methods A
Attachment 1: Uchiyama_et_al._-_2016_-_30-ps_time_resolution_with_segmented_scintillation_counter_for_MEG_II.pdf
Uchiyama_et_al._-_2016_-_30-ps_time_resolution_with_segmented_scintillation_counter_for_MEG_II.pdf Uchiyama_et_al._-_2016_-_30-ps_time_resolution_with_segmented_scintillation_counter_for_MEG_II.pdf Uchiyama_et_al._-_2016_-_30-ps_time_resolution_with_segmented_scintillation_counter_for_MEG_II.pdf Uchiyama_et_al._-_2016_-_30-ps_time_resolution_with_segmented_scintillation_counter_for_MEG_II.pdf
2008Conference with proceedings Search for lepton flavour violation with the MEG experimentNew Trends in High Energy Physics, Crimea 2008 
2006Conference with proceedings Performance of the Domino Ring Sampler in the MAGIC experimentBEAUNE 2005 4th International Conference on New Developments in Photodetection (NDIP05)Nucl. Instrum. Meth. A
ELOG V3.1.5-3fb85fa6